IEECAS OpenIR  > 加速器质谱中心
Effects of cone combinations on accurate and precise Mg-isotopic determination using multi-collector inductively coupled plasma mass spectrometry
Gou, LF (Gou, Long-Fei)1,2,3; Jin, ZD (Jin, Zhangdong)1; Galy, A (Galy, Albert)2; Sun, H (Sun, He); Deng, L (Deng, Li)1; Xu, Y (Xu, Yang)1,3
Corresponding AuthorGou, Long-Fei(goulf@ieecas.cn)
2019-02-28
Source PublicationRAPID COMMUNICATIONS IN MASS SPECTROMETRY
ISSN0951-4198
Volume33Issue:4Pages:351-360
Contribution Rank1
AbstractRationale High-precision determination of magnesium (Mg) isotopes can now be routinely achieved by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The analytical sensitivity and instrumental mass discrimination behavior of this method are, however, sensitive to the types of sample and skimmer cones used in these measurements, so it is important that these parameters should be investigated. Methods Using the sample-standard-bracketing method in the wet-plasma mode, four available combinations of sample and skimmer cones [Jet sample cone + H skimmer cone (Jet + H), standard sample cone + H skimmer cone (Standard + H), standard sample cone + X skimmer cone (Standard + X), and Jet sample cone + X skimmer cone (Jet + X)] were systematically investigated for peak shape, sensitivity, mass discrimination, accuracy, and precision in Mg-isotopic ratio determination using a Neptune plus MC-ICP mass spectrometer. Results The results showed that different cone combinations do not affect peak shapes but would significantly change the sensitivities for Mg-isotopic determinations. Compared with using the Standard + H, the sensitivities of Mg-isotopic determinations were enhanced by approximately a factor of 1.3, 1.4, and 1.9 by using the Standard + X, the Jet + H, and the Jet + X combinations, with the most stable mass discrimination behaviors obtained by the Jet + H. The instrumental mass fractionation slope for any combination of a modified cone geometry (i.e. Standard + X, Jet + X, and Jet + H) is 0.500, while it is 0.510 for the Standard + H. In addition, the mass discrimination behavior is related to Mg concentrations once the combination is set, indicating the necessity of concentration match during Mg-isotopic determination. Conclusions The precision and accuracy of the Jet + H combination are better than those of the other combinations, and this is further supported by the validation of the Mg-isotope data for four international reference materials: Cambridge-1, NASS-6, AGV-2, and BHVO-2. As the Jet + H combination also provides a high signal, this combination gives the most robust strategy for the highly precise and accurate determination of Mg isotopes.
DOI10.1002/rcm.8356
WOS KeywordMC-ICP-MS ; ENHANCED SENSITIVITY ; MAGNESIUM ; FRACTIONATION ; RATIO ; GEOCHEMISTRY ; CARBONATE ; SKIMMER ; CA
Indexed BySCI ; SCIE
Language英语
Funding ProjectNational Natural Science Foundation of China[41773149] ; State Key Laboratory of Loess and Quaternary Geology[Y752YQ3443] ; Chinese Academy of Sciences[132B61KYSB20170008] ; Chinese Academy of Sciences[QYZDJ-SSW-DQC033]
WOS Research AreaBiochemistry & Molecular Biology ; Chemistry ; Spectroscopy
Funding OrganizationNational Natural Science Foundation of China ; State Key Laboratory of Loess and Quaternary Geology ; Chinese Academy of Sciences
WOS SubjectBiochemical Research Methods ; Chemistry, Analytical ; Spectroscopy
WOS IDWOS:000457242400004
PublisherWILEY
Citation statistics
Cited Times:5[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.ieecas.cn/handle/361006/10944
Collection加速器质谱中心
Corresponding AuthorGou, LF (Gou, Long-Fei)
Affiliation1.Chinese Acad Sci, State Key Lab Loess & Quaternary Geol, Inst Earth Environm, Xian 710061, Peoples R China;
2.Univ Lorraine, CNRS, UMR7358, Ctr Rech Petrog & Geochim, F-54500 Vandoeuvre Les Nancy, France;
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
Recommended Citation
GB/T 7714
Gou, LF ,Jin, ZD ,Galy, A ,et al. Effects of cone combinations on accurate and precise Mg-isotopic determination using multi-collector inductively coupled plasma mass spectrometry[J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY,2019,33(4):351-360.
APA Gou, LF ,Jin, ZD ,Galy, A ,Sun, H ,Deng, L ,&Xu, Y .(2019).Effects of cone combinations on accurate and precise Mg-isotopic determination using multi-collector inductively coupled plasma mass spectrometry.RAPID COMMUNICATIONS IN MASS SPECTROMETRY,33(4),351-360.
MLA Gou, LF ,et al."Effects of cone combinations on accurate and precise Mg-isotopic determination using multi-collector inductively coupled plasma mass spectrometry".RAPID COMMUNICATIONS IN MASS SPECTROMETRY 33.4(2019):351-360.
Files in This Item:
File Name/Size DocType Version Access License
rcm.8356.pdf(911KB)期刊论文作者接受稿开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Gou, LF (Gou, Long-Fei)]'s Articles
[Jin, ZD (Jin, Zhangdong)]'s Articles
[Galy, A (Galy, Albert)]'s Articles
Baidu academic
Similar articles in Baidu academic
[Gou, LF (Gou, Long-Fei)]'s Articles
[Jin, ZD (Jin, Zhangdong)]'s Articles
[Galy, A (Galy, Albert)]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Gou, LF (Gou, Long-Fei)]'s Articles
[Jin, ZD (Jin, Zhangdong)]'s Articles
[Galy, A (Galy, Albert)]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.