Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements | |
Xu, YH (Xu, Yihong)[1,2]; Qiao, JX (Qiao, Jixin)[2] ; Hou, XL (Hou, Xiaolin)[2,3] ; Pan, SM (Pan, Shaoming)[1]; Roos, P (Roos, Per)[2] | |
2014-02-15 | |
发表期刊 | Talanta |
卷号 | 119页码:590-595 |
文章类型 | 期刊论文 |
摘要 | This paper reports an analytical method for the determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5×105 for 20 g soil compared to the level reported in the literature, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference values, revealing that the developed method for plutonium determination in environmental samples is reliable. The measurement results of 239+240Pu by alpha spectrometry agreed very well with the sum of 239Pu and 240Pu measured by ICP-MS. ICP-MS can not only measure 239Pu and 240Pu separately but also 241Pu. However, it is impossible to measure 238Pu using ICP-MS in environmental samples even a decontamination factor as high as 106 for uranium was obtained by chemical separation. |
关键词 | Pu Isotopes Anion Exchange Chromatography Extraction Chromatography Radiometric Techniques Icp-ms Environmental Samples |
DOI | 10.1016/j.talanta.2013.11.061 |
收录类别 | SCI ; EI |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ieecas.cn/handle/361006/9825 |
专题 | 加速器质谱中心 |
通讯作者 | Hou, XL (Hou, Xiaolin)[2,3] |
作者单位 | 1.The Key Laboratory of Coastal and Island Development of Ministry of Education, Nanjing University, Nanjing 210093, China; 2.Center for Nuclear Technologies, Technical University of Denmark, Risø Campus, Roskilde 4000, Denmark; 3.Xi'an AMS Center, SKLLQG, Institute of Earth Environment, CAS, Xi'an 710075, China |
推荐引用方式 GB/T 7714 | Xu, YH , Qiao, JX , Hou, XL ,et al. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements[J]. Talanta,2014,119:590-595. |
APA | Xu, YH , Qiao, JX , Hou, XL , Pan, SM ,& Roos, P .(2014).Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements.Talanta,119,590-595. |
MLA | Xu, YH ,et al."Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements".Talanta 119(2014):590-595. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Determination of plu(619KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论