IEECAS OpenIR  > 粉尘与环境研究室
Biases in ketone measurements using DNPH-coated solid sorbent cartridges
Ho, SSH (Ho, Steven Sai Hang)[ 1,2,3 ]; Chow, JC (Chow, Judith C.)[ 1,2 ]; Watson, JG (Watson, John G.)[ 1,2 ]; Ip, HSS (Ip, Ho Sai Simon)[ 4 ]; Ho, KF (Ho, Kin Fai)[ 1,3 ]; Dai, WT (Dai, Wen Ting)[ 1 ]; Cao, JJ (Cao, Junji)[ 1 ]
2014-02-21
发表期刊ANALYTICAL METHODS
卷号6期号:4页码:967-974
文章类型期刊论文
摘要

Biases associated with carbonyl measurement using active air sampling through a 2,4-dinitrophenylhydrazine (DNPH)-coated solid sorbent cartridge following the U.S. EPA Method TO-11A are known but have not been fully investigated. Ketones are less reactive than aldehydes in the derivatization with DNPH, resulting in poor collection efficiency. Field studies and laboratory experiments demonstrate the uncertainties associated with two ketones (i.e., acetone and methyl ethyl ketone [MEK]). Ketone collection efficiencies are inversely related to relative humidity (RH), sample flow rate, and sample duration. Since water is a product in the bidirectional derivatization of carbonyls, the reverse reaction competes with the forward reaction as RH increases. Laboratory experiments demonstrate that similar to 35-80% of the ketones can be lost for RH > 50% with a single DNPH cartridge at a temperature of 22 +/- 2 degrees C. Optimal sampling flow rates and sampling durations under high RH need to be determined in various environments to ensure tolerable collection efficiencies.

DOI10.1039/c3ay41636d
收录类别SCIE ; EI
语种英语
引用统计
被引频次:14[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ieecas.cn/handle/361006/9723
专题粉尘与环境研究室
通讯作者Ho, SSH (Ho, Steven Sai Hang)[ 1,2,3 ]
作者单位1.The State Key Laboratory of Loess and Quaternary Geology, Institute of EarthEnvironment Chinese Academy of Sciences, Xi'an, Shaanxi, 710075, China;
2.Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89512, USA;
3.Jockey Club School of Public Health and Primary Care, The Chinese University of HongKong, Hong Kong, P.R. China;
4.Hong Kong Premium Services and Research Laboratory, Lai Chi Kok, Kowloon, HongKong, P.R. China
推荐引用方式
GB/T 7714
Ho, SSH ,Chow, JC ,Watson, JG ,et al. Biases in ketone measurements using DNPH-coated solid sorbent cartridges[J]. ANALYTICAL METHODS,2014,6(4):967-974.
APA Ho, SSH .,Chow, JC .,Watson, JG .,Ip, HSS .,Ho, KF .,...&Cao, JJ .(2014).Biases in ketone measurements using DNPH-coated solid sorbent cartridges.ANALYTICAL METHODS,6(4),967-974.
MLA Ho, SSH ,et al."Biases in ketone measurements using DNPH-coated solid sorbent cartridges".ANALYTICAL METHODS 6.4(2014):967-974.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Biases in ketone mea(575KB)期刊论文作者接受稿开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ho, SSH (Ho, Steven Sai Hang)[ 1,2,3 ]]的文章
[Chow, JC (Chow, Judith C.)[ 1,2 ]]的文章
[Watson, JG (Watson, John G.)[ 1,2 ]]的文章
百度学术
百度学术中相似的文章
[Ho, SSH (Ho, Steven Sai Hang)[ 1,2,3 ]]的文章
[Chow, JC (Chow, Judith C.)[ 1,2 ]]的文章
[Watson, JG (Watson, John G.)[ 1,2 ]]的文章
必应学术
必应学术中相似的文章
[Ho, SSH (Ho, Steven Sai Hang)[ 1,2,3 ]]的文章
[Chow, JC (Chow, Judith C.)[ 1,2 ]]的文章
[Watson, JG (Watson, John G.)[ 1,2 ]]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。