Challenges on field monitoring of indoor air quality in china
Ho, Steven Sai Hang1,2; Huang, Yu1,3; Lee, Shun-Cheng4; Cao, Junji1,3
2017-04-01
Source PublicationINDOOR AND BUILT ENVIRONMENT
Volume26Issue:4Pages:576-584
SubtypeArticle
AbstractField monitoring is critical in the examination of indoor air quality (IAQ) which offers an integrated assessment of human exposure. A good measurement protocol includes appropriate methodologies and compliance of quality control and quality assurance procedures. In China, there has been a huge economic growth in the past 20 years and living standard for Chinese citizens has been improving with a rapid development in urban cities and infrastructures. With these developments, there have been a growth of increasing pollution sources, and IAQ has been a major concern to the government and many Chinese citizens with widespread reports of the coherent health impacts. However, the indoor monitoring in China is full of technical challenges. In this paper, we review the difficulties in conducting IAQ assessment in China. Techniques and practical consideration have been proposed accordingly.
KeywordIndoor Air Quality Field Monitoring China Measurement Protocols Exposure
WOS HeadingsScience & Technology ; Technology ; Life Sciences & Biomedicine
DOI10.1177/1420326X15626991
WOS KeywordSOLID-PHASE MICROEXTRACTION ; LARGE ENVIRONMENTAL CHAMBER ; VOLATILE ORGANIC-COMPOUNDS ; PARTICLE CONCENTRATIONS ; BUILDING PATHOLOGY ; PASSIVE SAMPLER ; SICK BUILDINGS ; VOC EMISSIONS ; FORMALDEHYDE ; OUTDOOR
Indexed BySCI
Language英语
WOS Research AreaConstruction & Building Technology ; Engineering ; Public, Environmental & Occupational Health
WOS SubjectConstruction & Building Technology ; Engineering, Environmental ; Public, Environmental & Occupational Health
WOS IDWOS:000400158700012
Citation statistics
Document Type期刊论文
Identifierhttp://ir.ieecas.cn/handle/361006/5430
Collection粉尘与环境研究室
Affiliation1.Chinese Acad Sci, Inst Earth Environm, Key Lab Aerosol Chem & Phys, Xian 710061, Peoples R China
2.Desert Res Inst, Div Atmospher Sci, Reno, NV USA
3.Chinese Acad Sci, Inst Earth Environm, SKLLQG, Xian, Peoples R China
4.Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
Recommended Citation
GB/T 7714
Ho, Steven Sai Hang,Huang, Yu,Lee, Shun-Cheng,et al. Challenges on field monitoring of indoor air quality in china[J]. INDOOR AND BUILT ENVIRONMENT,2017,26(4):576-584.
APA Ho, Steven Sai Hang,Huang, Yu,Lee, Shun-Cheng,&Cao, Junji.(2017).Challenges on field monitoring of indoor air quality in china.INDOOR AND BUILT ENVIRONMENT,26(4),576-584.
MLA Ho, Steven Sai Hang,et al."Challenges on field monitoring of indoor air quality in china".INDOOR AND BUILT ENVIRONMENT 26.4(2017):576-584.
Files in This Item:
File Name/Size DocType Version Access License
Challenges on field (126KB)期刊论文出版稿开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Ho, Steven Sai Hang]'s Articles
[Huang, Yu]'s Articles
[Lee, Shun-Cheng]'s Articles
Baidu academic
Similar articles in Baidu academic
[Ho, Steven Sai Hang]'s Articles
[Huang, Yu]'s Articles
[Lee, Shun-Cheng]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Ho, Steven Sai Hang]'s Articles
[Huang, Yu]'s Articles
[Lee, Shun-Cheng]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.