IEECAS OpenIR  > 加速器质谱中心
Accurate Determination of Plutonium in Soil by Tandem Quadrupole ICP-MS with Different Sample Preparation Methods
Xing, Shan1; Luo, Maoyi1; Yuan, Ni1; Liu, Daqian1; Yang, Yao1; Dai, Xiongxin1; Zhang, Weichao2; Chen, Ning2
通讯作者Xing, Shan(xingshan.yc@foxmail.com) ; Dai, Xiongxin(daixiongxin@cirp.org.cn)
2021-03-01
发表期刊ATOMIC SPECTROSCOPY
ISSN0195-5373
卷号42期号:2页码:62-70
摘要In this work, three commonly used digestion techniques, such as acid leaching with 8 M HNO3, aqua regia and lithium metaborate fusion, were employed to extract Pu from different types of soil samples widely found across China, and to establish the influence of the major interference elements (U, Hg, Pb, Tl, and Bi) on the accurate measurement of Pu by tandem quadrupole ICP-MS. The three sample digestion techniques yielded good results for the analysis of Pu isotopes originating from global atmospheric fallout. The U and Pb contributions to m/z=239 (2.38 and 0.3 cps) in samples digested by the fusion method using AGMP-1M resin were higher than those digested by the acid leaching methods (0.55 cps for U and < 0.03 cps for Pb), which implies that additional purification with TEVA resin would be required for low-level Pu determination in soil samples. By taking advantage of tandem quadrupole ICP-MS in the NH3/He mode, the count rates of Hg, Tl and Bi at m/z=239 (<0.01 cps) in the samples purified by using AGMP-1M resin and/or TEVA resin were found to be negligible for the different sample digestion methods.
DOI10.46770/AS.2021.011
关键词[WOS]PLASMA-MASS SPECTROMETRY ; ISOTOPE RATIO ; PU ISOTOPES ; ENVIRONMENTAL-SAMPLES ; SEDIMENT SAMPLES ; RADIONUCLIDES ; EXTRACTION ; ACTINIDES ; EXCHANGE ; RELEASE
收录类别SCI ; SCI
语种英语
资助项目China Institute for Radiation Protection (CIRP) ; Scientific Research Program for Young Talents of the China National Nuclear Corporation ; Ministry of Science and Technology of China[2015FY110800] ; State Key Laboratory of Loess and Quaternary Geology[SKLLQG1927]
WOS研究方向Spectroscopy
项目资助者China Institute for Radiation Protection (CIRP) ; Scientific Research Program for Young Talents of the China National Nuclear Corporation ; Ministry of Science and Technology of China ; State Key Laboratory of Loess and Quaternary Geology
WOS类目Spectroscopy
WOS记录号WOS:000621042400003
出版者ATOMIC SPECTROSCOPY PRESS LTD
引用统计
被引频次:16[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ieecas.cn/handle/361006/16110
专题加速器质谱中心
通讯作者Xing, Shan; Dai, Xiongxin
作者单位1.China Inst Radiat Protect, Taiyuan 030000, Peoples R China
2.Inst Earth Environm CAS, Xian AMS Ctr, State Key Lab Loess & Quaternary Geol, Xian 710061, Peoples R China
推荐引用方式
GB/T 7714
Xing, Shan,Luo, Maoyi,Yuan, Ni,et al. Accurate Determination of Plutonium in Soil by Tandem Quadrupole ICP-MS with Different Sample Preparation Methods[J]. ATOMIC SPECTROSCOPY,2021,42(2):62-70.
APA Xing, Shan.,Luo, Maoyi.,Yuan, Ni.,Liu, Daqian.,Yang, Yao.,...&Chen, Ning.(2021).Accurate Determination of Plutonium in Soil by Tandem Quadrupole ICP-MS with Different Sample Preparation Methods.ATOMIC SPECTROSCOPY,42(2),62-70.
MLA Xing, Shan,et al."Accurate Determination of Plutonium in Soil by Tandem Quadrupole ICP-MS with Different Sample Preparation Methods".ATOMIC SPECTROSCOPY 42.2(2021):62-70.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xing, Shan]的文章
[Luo, Maoyi]的文章
[Yuan, Ni]的文章
百度学术
百度学术中相似的文章
[Xing, Shan]的文章
[Luo, Maoyi]的文章
[Yuan, Ni]的文章
必应学术
必应学术中相似的文章
[Xing, Shan]的文章
[Luo, Maoyi]的文章
[Yuan, Ni]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。