ANALYSIS OF URINE FOR PURE BETA EMITTERS: METHODS AND APPLICATION | |
Hou, XL (Hou, Xiaolin)[1,2] | |
2011-08-30 | |
发表期刊 | HEALTH PHYSICS |
卷号 | 101期号:2页码:159-169 |
文章类型 | 期刊论文 |
摘要 | Bioassay for individual radionuclides is an essential and first step in estimation of radiation risk to nuclear facilities workers and people who are exposed to the contaminated environment in the event of a nuclear accident or radiological attack. Urine is a frequently used biological sample for this purpose. Tritium and (14)C are important radionuclides for workers in nuclear reactors and radiopharmaceutical laboratories. A method for the determination of tritium and (14)C in organic and inorganic forms in urine has been developed. It involves activated charcoal absorption of organic matter followed by combustion to separate tritiated water from organically-bound tritium. Inorganic (14)C from organically-bound (14)C, the separated tritium and (14)C were measured using liquid scintillation counting. Iodine-129, a long-lived beta emitter, is normally released to the atmosphere during the operation of nuclear facilities, especially in reprocessing plants. The high concentration of iodine in the thyroid makes this radionuclide an important source of exposure to exposed populations. A simple method has been developed in this work for the determination of (129)I in urine by anion exchange preconcentration, extraction purification and liquid scintillation counting. Using accelerator mass spectrometry, urine samples can be analyzed for low level (129)I in both organic and inorganic forms after active charcoal adsorption and solvent extraction separation. Condensed water collected daily from the reactor hall in a Danish research reactor and monthly urine samples from the staff working in the reactor building were collected from 2003-2010 and analyzed using this method, and the results are presented and discussed. Health Phys. 101(2):159-169; 2011 |
DOI | 10.1097/HP.0b013e31821497c0 |
收录类别 | SCI |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ieecas.cn/handle/361006/10295 |
专题 | 加速器质谱中心 |
通讯作者 | Hou, XL (Hou, Xiaolin)[1,2] |
作者单位 | 1.Risø National Laboratory for Sustainable Energy, TechnicalUniversity of Denmark, NUK-202, DK-4000, Roskilde, Denmark; 2.Xi’an AMS centre and SKLLQG, Institute of Earth Environment,Chinese Academy of Science, Xi’an, 710075, China |
推荐引用方式 GB/T 7714 | Hou, XL . ANALYSIS OF URINE FOR PURE BETA EMITTERS: METHODS AND APPLICATION[J]. HEALTH PHYSICS,2011,101(2):159-169. |
APA | Hou, XL .(2011).ANALYSIS OF URINE FOR PURE BETA EMITTERS: METHODS AND APPLICATION.HEALTH PHYSICS,101(2),159-169. |
MLA | Hou, XL ."ANALYSIS OF URINE FOR PURE BETA EMITTERS: METHODS AND APPLICATION".HEALTH PHYSICS 101.2(2011):159-169. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Analysis of urine fo(751KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 请求全文 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Hou, XL (Hou, Xiaolin)[1,2]]的文章 |
百度学术 |
百度学术中相似的文章 |
[Hou, XL (Hou, Xiaolin)[1,2]]的文章 |
必应学术 |
必应学术中相似的文章 |
[Hou, XL (Hou, Xiaolin)[1,2]]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论