Recovering laboratory doses using fine-grained quartz from Chinese loess | |
Wang, XL (Wang, X. L.)[1]; Wintle, AG (Wintle, A. G.)[2,3]; Du, JH (Du, J. H.)[1]; Kang, SG (Kang, S. G.)[1]; Lu, YC (Lu, Y. C.)[1] | |
2011-10-30 | |
发表期刊 | Radiation Measurements |
卷号 | 46期号:10页码:1073-1081 |
文章类型 | 期刊论文 |
摘要 | Here we report the results of dose recovery experiments carried out on fine-grained quartz from a Holocene sample in Chinese loess. Optical bleaching prior to giving a 9.35 Gy dose in the laboratory was carried out using artificial light sources, namely blue light emitting diodes (LEDs) and a solar simulator, followed by more than 24 h storage at room temperature. Stimulating the quartz with blue LEDs at room temperature resulted in overestimation of the recovered dose, whereas using the same stimulation time at temperatures above 150 degrees C resulted in the correct value for the recovered dose. Exposure to the solar simulator for times less than 200 min resulted in overestimation of the dose, whereas progressive underestimation was found for longer bleaching times. When doses of up 5333 Gy were given ahead of a 200 min exposure to the solar simulator, the dose recovered depended upon the magnitude of the previous dose, thus questioning the general application of a simple dose recovery experiment. |
关键词 | Quartz OSL SAR Optical bleaching |
DOI | 10.1016/j.radmeas.2011.07.022 |
收录类别 | SCI |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ieecas.cn/handle/361006/10271 |
专题 | 现代环境研究室 |
通讯作者 | Wang, XL (Wang, X. L.)[1] |
作者单位 | 1.SKLLQG, Institute of Earth Environment, Chinese Academy of Sciences, 10 Fenghui S. Road. Hi-Tech Zone, Xi’An 710075, PR China; 2.Institute of Geography and Earth Sciences, Aberystwyth University, Aberystwyth SY23 3DB, UK; 3.McDonald Institute for Archaeological Research, University of Cambridge, Downing Street, Cambridge CB2 3ER, UK |
推荐引用方式 GB/T 7714 | Wang, XL ,Wintle, AG ,Du, JH ,et al. Recovering laboratory doses using fine-grained quartz from Chinese loess[J]. Radiation Measurements,2011,46(10):1073-1081. |
APA | Wang, XL ,Wintle, AG ,Du, JH ,Kang, SG ,&Lu, YC .(2011).Recovering laboratory doses using fine-grained quartz from Chinese loess.Radiation Measurements,46(10),1073-1081. |
MLA | Wang, XL ,et al."Recovering laboratory doses using fine-grained quartz from Chinese loess".Radiation Measurements 46.10(2011):1073-1081. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Recovering laborator(664KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论