Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation
Zhang, LY (Zhang, Luyuan)[ 1,2 ]; Hou, XL (Hou, Xiaolin)[ 1,2 ]; Zhou, WJ (Zhou, Weijian)[ 1,2,4 ]; Chen, N (Chen, Ning)[ 1,2 ]; Liu, Q (Liu, Qi)[ 1,2,3 ]; Luo, MY (Luo, Maoyi)[ 2,4 ]; Fan, YK (Fan, Yukun)[ 1,2,3 ]; Fu, YC (Fu, Yunchong)[ 1,2 ]
2013-01-30
发表期刊NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS
卷号294页码:276-280
文章类型期刊论文
摘要

I-129 has been successfully applied as tracer in environmental, geological, and oceanographic research. For samples with low stable iodine concentration and ultra low level I-129, the sample preparation technique to separate iodine prior to AMS measurement has been a bottleneck, limiting the applicability of I-129 We have reported a carrier-free method, using coprecipitation, to avoid the potential introduction of I-129 through the use of stable iodine carrier iodine. In this work, the detection limit and the analytical uncertainty of this method are investigated and minimum sample amount required to obtain reliable analytical results are estimated. The method is validated with a series of samples in ranges of known iodine concentrations and I-129/I-127 ratios. The results confirm our previous conclusion that an AMS target containing 5.0 mu g iodine can be used for analyzing samples with I-129/I-127 > 10(-12), and that for samples with I-129/I-127 < 10(-13) more than 25 mu g iodine is necessary.

关键词Iodine-129 Carrier Free Coprecipitation Ams Minimum Sample Amount Detection Limit
DOI10.1016/j.nimb.2012.06.023
收录类别SCI ; EI
语种英语
引用统计
被引频次:7[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ieecas.cn/handle/361006/10051
专题加速器质谱中心
通讯作者Hou, XL (Hou, Xiaolin)[ 1,2 ]
作者单位1.SKLLQG, Institute of Earth Environment, China Academy of Sciences, Xi’an 710075, China;
2.Xi’an AMS Center, Xi’an 710061, China;
3.Graduate University of the Chinese Academy of Science, Beijing 100049, China;
4.Xi’an JiaoTong University, Xi’an 710049, China
推荐引用方式
GB/T 7714
Zhang, LY ,Hou, XL ,Zhou, WJ ,et al. Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,2013,294:276-280.
APA Zhang, LY .,Hou, XL .,Zhou, WJ .,Chen, N .,Liu, Q .,...&Fu, YC .(2013).Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,294,276-280.
MLA Zhang, LY ,et al."Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS 294(2013):276-280.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Performance of Accel(575KB)期刊论文作者接受稿开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, LY (Zhang, Luyuan)[ 1,2 ]]的文章
[Hou, XL (Hou, Xiaolin)[ 1,2 ]]的文章
[Zhou, WJ (Zhou, Weijian)[ 1,2,4 ]]的文章
百度学术
百度学术中相似的文章
[Zhang, LY (Zhang, Luyuan)[ 1,2 ]]的文章
[Hou, XL (Hou, Xiaolin)[ 1,2 ]]的文章
[Zhou, WJ (Zhou, Weijian)[ 1,2,4 ]]的文章
必应学术
必应学术中相似的文章
[Zhang, LY (Zhang, Luyuan)[ 1,2 ]]的文章
[Hou, XL (Hou, Xiaolin)[ 1,2 ]]的文章
[Zhou, WJ (Zhou, Weijian)[ 1,2,4 ]]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。